- 0Cart
-
Your shopping cart is empty.
-
more items in the cart...
Cart Total: $0.00
Proceed to Checkout
Your shopping cart is empty.
Cart Total: $0.00
Proceed to Checkout
Item specifics
Product Description
ANCEL AC3000 Refrigeration Digital Manifold Gauge Meter HVAC Tools Vacuum Pressure Temperature Tester For Air Conditioning Gauge The intelligent electronic refrigerant group instrument is an auxiliary instrument for the installation, testing and maintenance of refrigeration equipment such as air conditioners and cold storage. The instrument has double pressure test, dual temperature test (need test clip,not include), digital readout, multi-unit switching, multi-mode function and built-in refrigerant database. The instrument uses high-strength engineering plastics and flexible non-slip silicone design, the whole machine is solid and comfortable to hold. Built-in 32-bit digital processing unit and high-accuracy data acquisition unit, high data and stability. Large-size liquid crystal display, LCD backlight support, data display clear and easy to read, convenient light operation. Long-life valve switch, 1/4-inch standard interface design to ensure that the instrument's durability and versatility. Features: MUST HAVE -- The intelligent electronic refrigerant group instrument is an auxiliary instrument for the installation, testing and maintenance of refrigeration equipment such as air conditioners, fridge and cold storage. HVAC System Gauge Set has double pressure test, dual temperature test, digital readout, multi-unit switching, multi-mode function and built-in refrigerant database. SUPER CONVENIENT TOOL -- The instrument can measure double pressure at the same time, as well as dual temperature measurement, with automatic multi-unit pressure conversion, automatic conversion of temperature Celsius / Fahrenheit, to facilitate different needs. WHAT YOU CAN GET MORE -- Built-in 89 kinds of refrigerant pressure-evaporation temperature database, also calculate the subcooling superheat, to facilitate direct reading of operating process data. Also it tests percentage of vacuum measurement, pressure leak measurement, leak time speed record. It is deserved to have this multi-functional, accurate and simply operated digital manifold let you do the job right. PREMIUM DESIGN -- Large-size liquid crystal display, LCD backlight support, data display clear and easy to read, convenient light operation. Long-life valve switches, 1/4-inch standard interface design to ensure that the instrument's durability and versatility. HIGH-PRECISION AND WARRANTY -- The instrument uses high-strength engineering plastic and flexible non-slip silicone design. The whole machine is solid and comfortable to hold. Built-in 32-bit digital processing unit and high-precision data acquisition unit, high data and stability. [3-YEAR WARRANTY]: Three-year warranty and lifetime maintenance. Packing List: 1 * Digital Manifold Gauge 1 * User manual (in English) Note: Battery is not included in the package due to transportation reason.You can buy this battery directly in your store, very convenient, cheap, please understand, thank you (four 1.5v Alkaline batteries) Specifications: Pressure test: gauge pressure Pressure test unit: Kpa; Mpa; bar; inHg; PSI. Pressure test range: 0 Kpa – 6000 Kpa Pressure test resolution: 1 Kpa Pressure test accuracy: +/- 0.5 %(FS)+ 5dgt Pressure overload limit: 10000 Kpa (10 Mpa; 100 bar;) Vacuum test: relative vacuum Vacuum test unit: Kpa; Mpa; bar; inHg; PSI. Vacuum test range: -101 Kpa – 0 Kpa Vacuum test resolution: 1 Kpa Temperature test unit: °C (Celsius), °F (Fahrenheit) Temperature test range: -40°C–150°C (-40°F–302°F) Temperature test resolution: 0.1°C (-40°C–99.9°C), 1°C (100°C–150°C) 0.1°F (-40°F–99.9°F), 1°F (100°F–302°F) Temperature test accuracy: +/- 0.5 °C + 2dgt +/- 0.9 °F + 2dgt Built-in 89 kinds of refrigerant NIST: According to AmericanNIST standard Power Supplies: 4 X 1.5V (SIZE.AA / LR6) Battery not include Size: 170 * 110 * 50mm / 6.7 * 4.3 * 2.0in Package size: 200 * 150 * 80mm / 7.9 * 5.9 * 3.0in Package weight: 950g / 2.09lb EVAPORATION/CONDENSING PRESSUREAND TEMPERATURETEST PRESSURE LEAKAGE TEST Calculate the pressure difference between the initial test pressure and the second test pressure to determine if the refrigerant is leaking. HIGH/LOW PRESSURE TEMP. TEST The temperature of the refrigerant in the high/low pressurepipelines of the air conditioning system. BUILT-N 89 kinds of refrigerant database: Wide range of applications: Refrigerant type can be set filled with refrigerant throgh the vsual window It can be set according to the type of refrigerant that the car needs to fil the refrigerant filling status can be observed through a viewable window. Refrigerantion digital manifold gauge Button function display 0. Clamp-on temperature probe socket 1. LCD display 2. Function button 3. Run/Stop button 4. Zero button 5. R+/R-Refrigerant type selection buttons 6. Backlit button 7. Unit button 8. °C/°F button 9. Power button 10. High pressure valve 11. Refrigerant observation window 12. Pressure release valve 13. Refrigerant inlet/vacuum pump inlet 14. Low pressure valve 15. 1/4 inch high pressure inlet Pcakge list |