Item specifics
-
Brand Name
AUTOOL
-
Origin
CN(Origin)
-
testing and maintenance
air conditioners
fridge and cold storage
-
Vacuum test
relative vacuum
-
American NIST
Built-in 89 kinds of refrigerant NIST
-
Features 1
double pressure test
-
Features 2
dual temperature test
-
Features 3
digital readout
-
Features 4
multi-unit switching
-
Features 5
pressure leak measurement
-
Features 6
leak time speed record
-
Pressure
-101Kpa to 6Mpa
-
Three-color hose forehead length
1.5M
-
item
HVAC Vacuum Double Pressure Refrigerant Gauge Meter
DUOYI DY517A Digital Manifold Gauge Refrigeration Pressure Tester Vacuum Temperature Meter Air Conditioning Valve Tool PK HAVC TESTO The intelligent electronic refrigerant group instrument is an auxiliary instrument for the installation,
testing and maintenance of refrigeration equipment such as air conditioners,fridge and cold storage.
The instrument has double pressure test, dual temperature test , digital readout, multi-unit switching,
multi-mode function and built-in refrigerant database.
The instrument uses high-strength engineering plastics and flexible non-slip silicone design,
the whole machine is solid and comfortable to hold.
Built-in 32-bit digital processing unit and high-precision data acquisition unit, high data and stability.
Large-size liquid crystal display, LCD backlight support, data display clear and easy to read, convenient light operation.
Long-life valve switch, 1/4-inch standard interface design to ensure that the instrument's durability and versatility.
The instrument can measure double pressure at the same time, as well as dual temperature measurement ,
with automatic multi-unit pressure conversion, automatic conversion of temperature Celsius / Fahrenheit,
to facilitate different needs. Built-in 89 kinds of refrigerant pressure-evaporation temperature database,
also calculate the subcooling superheat, to facilitate direct reading of operating process data.
Also it tests percentage of vacuum measurement; pressure leak measurement, leak time speed record.
It is deserved to have this multi-functional, accurate and simply operated digital manifold let you do the job right. Built-in 89 kinds of refrigerant NIST According to American NIST standard EC/EN61010-1 safety standards for design and production. 1) The pressure measured by the digtal manifold pressure tester is gauge pressure. 2) Pressure testing ranges from -101Kpa to 6Mpa (-0.1bar to 60bar). 3) The limit pressure is 10 Mpa (100 bar). 4) The maximum operating pressure of standard hose is 600 PSI ( approximate 4.13 Mpa, 41.3 bar ). The limit pressure is 3000 PSI approximate 20.68 Mpa, 206.8 bar ). 5) Please confirm the rated pressure value of the tested equipment before testing.Do not use it if it exceeds the range of the instrument. Also for DY517A, if the packed hoses does not match the pressure requirement, you can use suitable replacements for testing. 6) Do not use and store the instrument in high temperature, high humidity, flammable, explosive and strong electromagnetic fields. 7) Please do not change the instrument internal circuit, to avoid any damage of the instrument or danger occurring. 8) Please wear qualified protective equipment to protect user during testing. 9) Please use the instrument in a well-ventilated environment to prevent inhalation of toxic gases. Product specifications Pressure test: gauge pressure Pressure test unit: Kpa; Mpa; bar; inHg; PSI. Pressure test range: 0 Kpa – 6000 Kpa Pressure test resolution: 1 Kpa Pressure test accuracy: +/- 0.5 %(FS)+ 5dgt Pressure overload limit: 10000 Kpa (10 Mpa; 100 bar;) Vacuum test: relative vacuum Vacuum test unit: Kpa; Mpa; bar; inHg; PSI. Vacuum test range: -101 Kpa – 0 Kpa Vacuum test resolution: 1 Kpa Temperature test unit: °C (Celsius), °F (Fahrenheit) Temperature test range: -40°C–150°C (-40°F–302°F) Temperature test resolution: 0.1°C (-40°C–99.9°C), 1°C (100°C–150°C) 0.1°F (-40°F–99.9°F), 1°F (100°F–302°F) Temperature test accuracy: +/- 0.5 °C + 2dgt +/- 0.9 °F + 2dgt Built-in 89 kinds of refrigerant NIST: According to American NIST standard Power Supply: 4 X 1.5V (SIZE.AA / LR6) Battery not include Dimensions: 170*110*50mm weight: 950g Packing list: 1x Refrigerantion Digital Manifold Gauge 1x User Manual (in English) 2x Temperature Clip 3x Test Pipe (1.5M) 1x Suitcase Battery not include Notes: 1. Due to the different monitor and light effect, the actual color of the item might be slightly different from the color showed on the pictures. Thank you! 2. Please allow slight measuring deviation due to manual measurement.
|