Item specifics
-
Origin
CN(Origin)
-
Type
Test Instruments
-
Model Number
DYXZ-02
-
Model Number
DYXZ-02
-
Power
3V DC (AA 1.5V*2)
-
Max input voltage
600V AC
-
Dimension
110mm*70mm*30mm
-
Insulation
5.4K Vrms
-
Max rated power
300mVA
-
Type1
Phase Detectors
-
Type2
Phase Rotation Monitor
-
Type3
Non-Contact Phase Sequence Detector
-
Type4
Phase Sequence Meter
DYXZ-02 Phase Sequence Detector Phase Meter Non-Contact Detector Indicator Detector Meter LED Display 3 Phase Tester
DYXZ-02 non-contact phase rotation tester designs for quick , easy and accurate detection of three phase sequence in motor installation and repair . The non-connection to insulated conductor avoids uncertain and difficult connections to bare high voltage wires
This is a phase detector, designed to perform phase sequence checks and live line checks of a 3-phase circuit using a static induction voltage clip. The static induction voltage clips are used to be able to clip on a cladded wire. It is small with a CAT 600V safety rating. Red LED lamps are used to make the indication visible in dimly lit areas. The direction of phase sequence can be checked easily using the LED lamps, which blink in order.
Specifications 1). Basic Specifications Function | Phase detection (positive/negative) | Voltage detection method | Static induction | Object to be connected | Insulated wire (nominal sectional area of the conductor: 2 to 120mm2, finished outer diameter: up to 17mm) | Performance-guarantee voltage range | 3-phase, 70V to 600 VAC (sine wave,continuous) | Operating frequency range | 45Hz to 66Hz |
2). Display Phase-detection indication | Positive phase sequence: The four phase-sequence lamps blink order (clockwise) and the buzzer sounds intermittently. Negative phase sequence: The four phase-sequence lamps blink in order (counterclockwise) and the buzzer sounds continuously. | Line-voltage indication | R-S lamp, S-T lamp | Power indication | Power ON lamp: lights up (Power ON) blinks (Battery Low) |
3). General Specifications Operating temperature and humidity | -10 to 40(32 to 104), 80%RH or less ( with no condensation) | Storage temperature and humidity | -20 to 60 (-4 to 140), 80%RH or less (with no condensation) | Location for use | Altitude up to 2000m(6562 feet), indoors | Maximum rated voltage to earth | 600V | Dielectric strength | 5.4kVrms | Power supply | Rated supply voltage 1.5VDC×2 Two AA size batteries | Maximum rated power | 300mVA | Continuous operating time* | Approx.70 hours(Power ON, Standby state, using R6P manganese battery) *Battery life | Auto Power Off (This function can not Be canceled.) | The power will be turned off automatically if the Instrument remains idle for 15 minutes after the power is turned on. To reset, turn the power on again using the Power ON switch. | Cable length | Approx. 0.7m | Dimensions and mass | Approx. 70W×75H×30Dmm(2.76W×2.95H×1.18D) (excluding projections), Approx. 200g(7.1oz) | Applicable standards | Safety EN61010-1:2001,EN61010-031:2002 Pollution degree2, Measurement category CAT III(600V)(anticipated transient overvoltage 6000V) EMC EN61326:1997+A1:1998+A2:2001 |
Test operation 1. Phase Detection CAUTION ! HIGH VOLTAGE ! (1)Connection: Connect the three non-contact alligator clips to the three phase power cables. (2)The symbol or each clip should be placed at the center of each cables. (3)Press "ON",lightA,B,C flashes once to power on the tester. (4)In case the A,B,C are lit up , R is on if positive CW is detected. If in negative CCW, L is on. If one or more of light A,B,C does not light up , it means the relevant phase is open. In this case, R or L does not represent the indication. (5)Press "OFF" to shut down the tester after use 2.Live Voltage Detection CAUTION ! HIGH VOLTAGE ! (1)Connect any of the alligator clips to the conductor. If the conductor is powered on (Voltage within 70~600V AC),the relevant light A,B,C should light up.This can quickly determine if the conductor is powered on. (2)Clips and lights reference table Clips | Lights | A (yellow ,left) | Light A | B(green ,middle) | Light B | C(red , right) | Light C |
Packing list: 1*Phase Detector 1*Accessory bag 1*Certificate of conformity 1*English manual
|